DepthUMI

Active Depth for Universal Manipulation Interfaces

Anonymous authors Under review

One wrist-contained sensing system for accurate demonstration motion
and geometry-aware robot learning.

Figure 1. A single calibrated interface connects handheld demonstrations, recovered motion and geometry, and robot execution.

Abstract

Universal Manipulation Interfaces (UMIs) scale robot learning by allowing people to collect demonstrations beyond the robot workspace. Their portability, however, shifts the bottleneck to sensing: a wrist-contained device must recover precise motion despite occlusions and rapid viewpoint changes, while preserving the local 3D geometry needed by the policy. We present DepthUMI, a handheld interface in which the same learned active-depth source supports both motion recovery and policy observation. Rather than treating these as separate sensing problems, DepthUMI combines wide-field stereo, high-rate inertial sensing, and learned active depth in one calibrated assembly. Wide-field visual–inertial reconstruction estimates the demonstrated trajectory, and a calibrated transfer maps camera motion into gripper action supervision. In parallel, learned near-field geometry constrains reconstruction and supplies metric point-cloud observations for policy learning.

A simulation study guides the sensing configuration, followed by real-world evaluation of the resulting system. On an instrumented validation rig evaluated against an external Vive reference, DepthUMI achieves an overall mean wrist-camera translation error below 3 mm without using that reference as estimator input. Across three manipulation tasks spanning articulated pulling, peg insertion, and constrained block extraction, learned geometry matches the strong baseline on the coarse pulling task and yields its clearest gains when local geometric precision is decisive. Together, these results show that a single wrist-contained sensing system can produce accurate action supervision and geometry-aware policy inputs.

Real-world evaluation

Results

From accurate demonstrations to contact-sensitive manipulation.

Geometry matters at contact.

Selected real-world rollouts on a Franka Research 3.

Explore the tasks

Precise alignment before contact.

DPRGB

Failure
Peg not seated

DP3Learned active depth

Success
Peg seated
4× speed No audio

Selected examples; all evaluation counts are reported below. Continuous attempts, trimmed at the ends and shown at 4× speed without audio. Independent recordings do not measure relative execution speed.

Manipulation success.

Ten physical trials per task and policy, with shared demonstrations and action supervision.

Successes per ten trials for each task and policy. Total over thirty trials.
PolicyObservationDrawer
opening
Peg
insertion
Block
extraction
Total
DPRGB7/101/101/109/30
DP3Factory depth5/100/101/106/30
DP3Learned active depth8/107/105/1020/30

Successes / attempts; 10 trials per task and policy. Shared demonstrations, action supervision, and data splits. The two DP3 variants also share architecture and training budget, changing the geometry source.

The largest observed gains over RGB occur in peg insertion (1 → 7 successes) and block extraction (1 → 5). Drawer opening changes by one success. Factory depth alone does not reproduce these gains.

Evaluation protocol and 95% confidence intervals

Each policy is evaluated for 10 attempts per task under bounded pose changes of up to ±5 cm and ±15°, with varied robot initialization. All attempts begin before grasping. Checkpoints are selected using development rollouts; the formal outcomes remain separate.

Observed success rate and two-sided Wilson 95% interval (paper Table 15)
PolicyDrawer openingPeg insertionBlock extraction
DP · RGB70% [39.7, 89.2]10% [1.8, 40.4]10% [1.8, 40.4]
DP3 · Factory depth50% [23.7, 76.3]0% [0.0, 27.8]10% [1.8, 40.4]
DP3 · Learned depth80% [49.0, 94.3]70% [39.7, 89.2]50% [23.7, 76.3]

These are physical rollout repetitions, not independent training seeds. Counts are preserved; the intervals convey the uncertainty associated with ten attempts.

Reliable geometry, close to contact.

Factory depth can become sparse during near-field approach. Learned active depth preserves local surface structure for point-cloud policy inputs.

Figure 7Onboard deployment geometry

In the paper ↗
Matched wrist RGB, left/right IR, factory and learned depth, and point-cloud observations across all three tasks. Dark depth pixels indicate invalid or out-of-range measurements; the depth color scale is in metres.Full resolution ↗

Accurate motion. Useful supervision.

Wrist motion is scored against an external Vive reference used only for evaluation. We also measure error over the relative action horizons used in policy supervision.

Figure 5Synchronized recording and trajectory reconstruction

In the paper ↗
Synchronized RGB, left/right IR, factory depth, learned IR depth and the resulting point cloud accompany reconstructed camera trajectories and translation errors. The factory and learned depth panels share a display scale. Vive alignment is used only for evaluation; camera-frame error is distinct from TCP error.Full resolution ↗

Wrist motion recovery

Mean translation ATE 7 real recordings

Mean translation absolute trajectory error, in millimetres. Lower is better.
Motion sourceATE (mm) ↓
T265 SDK119.223
ORB-SLAM3 stereo–inertial3.117
Fisheye depth2.873
Learned IR depth2.875

Fisheye and learned-IR means differ by just 0.002 mm, a negligible gap at this precision. Lower is better.

Action-horizon error

Relative translation RMSE 24 common demonstrations

Action-relative translation root mean square error, in millimetres. Lower is better.
HorizonORB-SLAM3Learned IR
1 step2.831.51
3 steps4.342.91
6 steps6.174.53
16 steps9.307.27

All errors in mm; lower is better. Tracking-derived supervision error, not policy train/test prediction error.

Per-recording tracking results · all seven sequences
Paper Table 1 · real wrist-camera translation ATE (mm; lower is better)
RecordingT265 SDKORB-SLAM3Fisheye depthLearned IR depth
N12.9001.783 ± 0.1881.549 ± 0.0891.453 ± 0.065
N26.4052.874 ± 0.4382.067 ± 0.0821.993 ± 0.023
N39.8268.828 ± 0.0358.820 ± 0.0228.831 ± 0.032
N44.8171.071 ± 0.0471.092 ± 0.0751.183 ± 0.077
N54.2091.155 ± 0.0700.996 ± 0.0171.023 ± 0.025
W1684.1113.068 ± 0.0712.617 ± 0.0612.636 ± 0.069
W2122.2943.036 ± 0.2262.972 ± 0.0113.004 ± 0.067
Average119.2233.1172.8732.875

N1–N5: normal background. W1–W2: low-texture white-cloth background. Offline entries show mean ± sample standard deviation over five runs; the average equally weights all seven recordings.

Reconstruction, action supervision and execution · full comparison

Thirty cup pick-and-place demonstrations connect camera-level reconstruction, action labels, direct replay and policy execution. The common action-error set contains 24 complete demonstrations.

Paper Table 2 · global reconstruction, action-relative error and execution
Motion sourceGlobal
support
Trans.
ATE (mm)
Rot.
ATE (°)
k = 1k = 3k = 6k = 16ReplayPolicy
Vive reference30/30ref.ref.ref.ref.ref.ref.5/55/5
T265 SDK30/3018.4682.9147.82 / .2414.00 / .4019.77 / .5629.75 / .801/53/5
ORB-SLAM328/305.1771.3622.83 / .184.34 / .346.17 / .509.30 / .685/54/5
Fisheye depth30/302.7821.1911.42 / .152.91 / .324.49 / .497.04 / .685/55/5
Learned IR depth30/302.7231.2141.51 / .152.91 / .324.53 / .497.27 / .685/55/5

Global columns report median cup-trajectory ATE on each method’s usable support. Action cells report median translation RMSE (mm) / rotation RMSE (°) on the 24 common demonstrations. Replay and policy are successes / five trials. Rollout success alone does not certify faithful global reconstruction.

Trajectory plots and time-resolved errors

Appendix · Figure 9Trajectory agreement across seven recordings

In the paper ↗
Each panel shows an evaluation-aligned camera trajectory relative to its initial Vive pose. Faint offline curves show all five runs and bold curves show their timestamp-wise means. Panels use independent planar scales: compare methods within a panel, not magnitudes across panels.Full resolution ↗

Appendix · Figure 10Time-resolved tracking error

In the paper ↗
Translation error against the evaluation-only Vive reference for N3 and W1. Lines and bands show mean ± sample standard deviation over five runs. N3 retains the frozen reference discontinuities; W1 uses a separately labeled scale to preserve millimetre-level structure.Full resolution ↗

Method

One sensing source. Two roles.

Collecting demonstrations away from the robot shifts the challenge to sensing. DepthUMI combines wide-field stereo, inertial sensing, and learned active depth in one calibrated handheld assembly.

Recover demonstration motion

Visual–inertial reconstruction and learned depth recover the wrist trajectory. A calibrated transfer maps camera motion into gripper action supervision.

Observe local geometry

The same learned depth source provides metric point clouds near the gripper, giving the policy local geometry for contact-sensitive manipulation.

Figure 4Active geometry for action supervision and policy observations

In the paper ↗
Wide-field stereo and inertia recover the demonstrated gripper trajectory. Learned active depth provides both geometric constraints and metric point-cloud observations. Calibrated poses define current-relative action targets; robot execution uses the same conventions with measured TCP state.Full resolution ↗

Action supervision. A calibrated transform transfers camera motion into gripper poses. One current TCP reference anchors the history and the predicted action chunk.

Policy observations. DP uses wrist RGB; DP3 uses 4,096 calibrated XYZ points from factory or learned active depth. Live history advances once per completed policy action.

Simulation-guided design

Sensing choices, tested in simulation.

Before fixing the hardware, we study where sensing should be placed and which visual, inertial and depth cues it should retain.

Figure 2Simulation-guided sensing design

In the paper ↗
RoboDojo tasks in Isaac Sim probe head and wrist sensing under furnished and low-texture conditions. Camera ATE is evaluated across stereo, inertial and depth configurations. All 220 solves are shown. Large marks and ranges show means and min–max (n = 3, except two bowl right-wrist learned-depth cells with n = 5).Full resolution ↗

Placement and appearance. Head and wrist views are tested across furnished and all-white scenes on three RoboDojo tasks. Sensing configurations are compared under the same recorded motion.

Complementary cues. Wide-field stereo preserves scene context, inertia supports motion estimation, and active IR contributes near-field geometry when visual appearance is unreliable.

Synchronized simulation observations

Appendix · Figure 11Synchronized simulation observations

In the paper ↗
Head and wrist observations at one Isaac Sim timestamp pair wide-field stereo and active IR with learned depth and simulator ground truth. Absolute error is in centimetres. The causal, kinematics-derived wrist-IMU window remains distinct from real measured inertia.Full resolution ↗

System & calibration

A calibrated, wrist-contained system.

Wide-field fisheye images, active-IR stereo and a dedicated IMU connect demonstration capture to metric motion and geometry.

Figure 3Device configurations and calibration protocol

In the paper ↗
The compact acquisition device, instrumented validation rig and robot-mounted sensor share calibrated geometry. Calibration covers camera intrinsics and extrinsics, camera–IMU spatial and temporal alignment, and camera-to-tool transfer. The Vive reference is used only for evaluation.Full resolution ↗

Spatial and temporal calibration. Camera geometry, camera–IMU transforms and clock offsets are calibrated together with the camera-to-tool chain. Device and host acquisition timestamps survive processing.

Reference versus measurement. The validation rig carries an evaluation-only Vive reference. The compact acquisition device retains one HI12 IMU and removes external pose tracking.

Appendix · Figure 8Photographed handheld and robot-mounted hardware

In the paper ↗
Front and rear views distinguish the instrumented validation rig from the compact acquisition device. The validation rig adds inertial streams and a Vive reference; the acquisition device uses one IMU and no external pose reference. Robot TCP state comes from kinematics.Full resolution ↗

Citation

Anonymous submission. Author information will be added after review.

@misc{depthumi2027,
  title  = {DepthUMI: Active Depth for Universal Manipulation Interfaces},
  author = {Anonymous},
  year   = {2027}
}